EIFS & Dryvit Restoration in Peachtree Corners
Many Peachtree Corners office, retail and multifamily buildings are clad in EIFS that is now decades old. We repair it with compatible materials, replace wet substrate behind it, renew its joints and recoat it, or convert it to a drainable design where that is the right answer.
- EIFS & Dryvit repair
- Joint & sealant renewal
- Facade recoats
- Drainable conversions
Request a commercial quote
Peachtree Corners commercial stucco & EIFS. Property managers, boards, owners & builders.
Older EIFS can be saved, if it is dry
EIFS was a natural choice for the office parks and shopping centers built in Peachtree Corners through the 1980s and 1990s: light, insulating and easy to shape into cornices, bands and reveals. Most of it was installed as barrier EIFS, which relies on the face of the wall and its sealant joints to keep every drop out. When a joint or a window perimeter fails, water that gets in has no planned way back out.
The good news is that a lot of that EIFS is still serviceable. The question is how much water has reached the sheathing. We survey with moisture probes at terminations, window corners and joints, then open the wall where readings are high. Wet or soft sheathing is replaced, the weather barrier is restored, and the EIFS is rebuilt with matching foam, mesh, base coat and finish.
Once the substrate is sound, restoration can be as simple as replacing the joints and recoating, or as thorough as converting elevations to a drainable system. We explain the options and their trade-offs in a written scope, so owners and boards can match the work to the building’s remaining life and their capital plan.

EIFS & Dryvit restoration in Peachtree Corners
Most EIFS problems come down to water at the edges or damage to a soft face. The scope depends on whether the substrate behind is still dry.
Wet substrate repair
Wet sections are cut out, damaged sheathing replaced with glass-mat gypsum board, and the wall rebuilt with new board, mesh, base coat and finish.
Joint & sealant renewal
Failed sealant at windows, storefronts and panel joints is replaced with backer rod and an EIFS-compatible sealant against a sound edge.
Facade recoats
A new finish coat over sound EIFS renews color and texture across an entire elevation or building without removing the system.
Barrier to drainable conversion
Failing barrier EIFS is removed and replaced with a drainable system over a weather barrier, elevation by elevation if needed.
Impact damage
Dents and punctures at entrances, loading areas and ground-floor corners are cut back, rebuilt with heavier mesh where needed and blended in.
Below-grade foam & termites
Foam board run into soil or under pavement gives termites a hidden path. We cut it back above grade and repair damaged framing.
Choosing the right EIFS scope
If moisture readings are low and damage is local, section repairs with new sealant joints and a matched finish are usually the right answer. If the facade has been patched many times or faded unevenly, a recoat across the elevation gives a uniform look and helps a dated building show better to tenants and prospects.
When barrier EIFS shows wet readings in many places, repairing spot by spot often just moves the problem. Converting to a drainable system, or to hard coat stucco or fiber cement on some elevations, can be the better long-term choice. We explain the options with readings and photos in front of you, separate urgent work from what can be phased, and document any change in scope for your approval before we proceed.
| Scope | Best for | Result |
|---|---|---|
| Section repair | Local damage, dry substrate | Blended to corners |
| Joint renewal | Failed sealant, sound wall | Edges closed |
| Facade recoat | Patched or faded elevations | Uniform building |
| Drainable conversion | Widespread wet barrier EIFS | New drainable system |
How an EIFS restoration runs
Restorations run elevation by elevation, so tenants and residents keep their entrances, parking and daily routine.
Identify & survey
We confirm whether the facade is barrier or drainable EIFS and take moisture readings to find the edges of any wet area on each elevation.
- System identified
- Readings mapped by elevation
- Photo documentation
Remove & rebuild
Damaged EIFS and wet sheathing come out. New sheathing, weather barrier and insulation board go in, with flashing corrected at the leak.
- Wet sheathing replaced
- Flashing corrected
- Foam kept above grade
Mesh, coat & finish
Base coat and reinforcing mesh are lapped into the existing wall, joints are sealed, and the finish is matched or the elevation recoated.
- Mesh lapped into old work
- Compatible materials
- Matched finish
Not sure if the building is EIFS or stucco?
EIFS sounds hollow and feels softer than cement stucco when tapped. We confirm it on the first site walk.
A city built in the EIFS era
The decades when much of Peachtree Corners was built were the decades EIFS dominated suburban commercial design.
Drive Technology Parkway or Peachtree Parkway and you will see the signatures: banded office facades with reveals at each floor line, foam cornices on retail towers, and smooth panels around ribbon windows. Each of those details has its own failure point, and we restore them with EIFS materials rather than cement patches that crack at the edges.
Banded office facades
Reveal joints and floor-line bands that collect water on older office buildings.
Foam cornices & towers
Retail and office trim with flat tops and cracked coatings that let water into the foam.
Barrier-to-drainable
Conversions for elevations where repeated wet substrate shows the original design is not working.
- Peachtree Corners
- Technology Park
- Technology Parkway
- Peachtree Parkway
- The Forum area
- Holcomb Bridge Road
- Norcross
- Duluth
- Berkeley Lake
- Dunwoody
EIFS restoration FAQ for Peachtree Corners buildings
What owners and managers ask when an older EIFS facade starts showing its age.
Is EIFS the same as Dryvit?
Do we have to tear off our EIFS?
Our Technology Park building has barrier EIFS. Should we convert it?
Will repaired EIFS match the rest of the building?
Does changing the color of an EIFS building in Peachtree Corners need approval?
Restore your EIFS instead of replacing it
Tell us about the building and what you are seeing. We will survey the EIFS and send a written restoration scope with options.